Shop Safety Manual
Environmental Health & Safety 1 v1.1
Shop Equipment Safety Checklist – Power
Press or Press Brake
☐
☐
OEM Operator’s Manual Readily Available?
☐
☐
All items marked “NO” must be corrected.
Section A – Installation
1 ☐ ☐ ☐
The machine is securely restrained to
prevent movement in accordance with the
machine manufacturer’s recommendations
or sound engineering practices.
8 CCR §3328(d)
2 ☐ ☐ ☐
The machine’s electrical attachment plug is
connected directly to the building’s wiring
and that wiring’s ampacity is rated for at
least 125% of the machine’s full load
current.
24 CCR 3 §670.4(A) (2022)
3
☐ ☐ ☐
The machine’s power cord and plug are in
good condition with no cuts or fraying of the
insulation.
8 CCR §3328(c)
4
☐ ☐ ☐
The machine is equipped with a means to
promptly disconnect power, such as a
switch, in case of emergency.
8 CCR §4001
5
☐ ☐ ☐
If the machine is powered by permanent
conductors from the building’s wiring, the
incoming power supply circuit is terminated
at a disconnecting means located
immediately adjacent to the machine.
24 CCR 3 §670.4(B) / NFPA 79 §5.1.9.6
(2021)
6
☐ ☐ ☐
The disconnecting means is legibly marked
to indicate the equipment it disconnects.
24 CCR 3 §110.22 / NFPA 79 §5.1.9.2
(2021)
7 ☐ ☐ ☐
All disconnecting means enclosures are
marked with a safety sign in accordance
with ANSI Z535.4 to warn qualified persons
of potential electric shock and arc flash
hazards.
24 CCR 3 §110.16 / NFPA 70E §130.5(H)