GAS GRIDDLE
MODELS:
GGM-24S, GGM-36S, GGM-48S
GGT-24S, GGT-36S, GGT-48S
OWNERS MANUAL
2M-Z23811 Rev. - December 14, 2020
is a registerd trademark of APW Wyott®, A Middleby Company. All rights reserved.
This manual includes material related to installation, use , cleaning, and care. Exploded view[s], as well as any available
parts list[s] and wiring diagram[s] pertaining to the unit[s] covered by this manual are also included.
This manual must be read and understood by all persons using or installing this appliance. Contact your Star dealer
if you have any questions concerning installation, use, or maintenance of this equipment.
DO NOT DISCARD THIS MANUAL.
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
GGT-36S
THOROUGHLY INSPECT YOUR UNIT ON ARRIVAL
This unit has been tested for proper operation before leaving our plant to ensure delivery of your unit
in perfect condition. However, there are instances in which the unit may be damaged in transit. In the
event you discover any type of damage to your product upon receipt, you must immediately contact the
transportation company who delivered the item to you and initiate your claim with that company. If this
procedure is not followed, it may aect the warranty status of the unit. If damage or loss is not apparent
until after equipment is unpacked, a request for inspection of concealed damage must be made with carrier
within 15 days. Please record the model number, serial number, voltage, and purchase date in the area
below at the time of receipt.
Model Number _______________________
Serial Number _______________________
Voltage _______________________
Purchase Date _______________________
MAINTENANCE AND REPAIRS
Contact your local authorized service agent for service or required maintenance. Please have the information
in the above fields ready when you call to ensure a faster service.
Using any part other than genuine APW Wyott factory supplied parts relieves the manufacturer of all liability.
Due to periodic changes in designs, methods, procedures, policies, and regulations, the specications
contained in this document are subject to change without notice. APW Wyott reserves the right to change
product specifi cations and design without notice. Such revisions do not entitle the buyer to corresponding
changes, improvements, additions or replacements for previously purchased equipment. While APW Wyott
exercises good faith eorts to provide information that is accurate, we are not responsible for errors or
omissions in information provided or conclusions reached as a result of using the specifi cations. By using
the information provided, the user assumes all risks in connection with such use.
PLEASE REFER TO THE WARRANTY PAGE FOR SPECIFIC WARRANTY INFORMATION.
AUTHORIZED SERVICE AGENT LISTING
Reference the listing provided with the unit or for an updated listing go to the website or call customer
service to find an agent.
Business hours: 8:00 a.m. to 4:30 p.m. Central Standard Time
Telephone: (800) 527-2100
Email: TechService@Partstown.com
Website: www.apwwyott.com
SAFETY SYMBOLS
These symbols are intended to alert the user to the
presence of important operating and maintenance
instructions in the manual accompanying the
appliance.
2M-Z23811: APW Wyott Series Gas Griddles
1
SPECIFICATIONS: Gas Griddle
MODEL: GGM-24S, GGM-36S, GGM-48S, GGT-24S, GGT-36S, GGT-48S
5.9 [150.4]
3.8 [97.4]
5.25 [133.3]
19.0 [481.5]
B
*UNITS OPERATE ON NATURAL GAS OR PROPANE GAS
4.0 [100.3]
SPECIFICATIONS
Model No.
(A) Width
Inches (cm)
(B) Depth
Inches (cm)
(C) Height
Inches (cm)
(D) Leg Width
Inches (cm)
No. Controls
BTU
Grid Area
Installed
Weight lbs.
(kg)
Shipping
Weight lbs.
(kg)
GGT-24S
24 (61.0) 29 (65.4) 15-1/2 (39.4) 19 (48.3)
2
40,000
498 SQ.IN.
3213 SQ. CM.
165 (74.8) 175 (79.4)
GGT-36S
36 (91.4) 29 (65.4) 15-1/2 (39.4) 32-3/4 (83.2)
3
60,000
747 SQ. IN.
4820 SQ. CM.
247 (112.0) 262 (118.8)
GGT-48S
48 (121.9) 29 (
65.4) 15-1/2 (39.4) 44-3/4 (113.7)
4
80,000
996 SQ. IN.
6426 SQ. CM.
330 (144.7) 350 (158.9)
A
C
MODEL
NO.
(A) WIDTH
Inches (cm)
(B) DEPTH
Inches (cm)
(C)
VHEIGHT
Inches (cm)
(D) LEG
WIDTH
Inches (cm)
NO.
CONTROLS
BTU GRID AREA
INSTALLED
WEIGHT
lb (kg)
SHIPPING
WEIGHT
lb (kg)
GGT-24S 24 (61.0) 29 (73.7) 15-1/2 (39.4) 19 (48.3) 2 40,000
498 SQ.IN.
3213 SQ. CM.
165 (74.8) 175 (79.4)
GGT-36S 36 (91.4) 29 (73.7) 15-1/2 (39.4) 32-3/4 (83.2) 3 60,000
747 SQ. IN.
4820 SQ. CM.
247 (112.0) 262 (118.8)
GGT-48S 48 (121.9) 29 (73.7) 15-1/2 (39.4)
44-3/4
(113.7)
4 80,000
996 SQ. IN.
6426 SQ. CM.
330 (144.7) 350 (158.9)
GGM-24S 24 (61.0) 29 (73.7) 15-1/2 (39.4) 19 (48.3) 2 40,000
498 SQ.IN.
3213 SQ. CM.
165 (74.8) 175 (79.4)
GGM-36S 36 (91.4) 29 (73.7) 15-1/2 (39.4) 32-3/4 (83.2) 3 60,000
747 SQ. IN.
4820 SQ. CM.
247 (112.0) 262 (118.8)
GGM-48S 48 (121.9) 29 (73.7) 15-1/2 (39.4)
44-3/4
(113.7)
4 80,000
996 SQ. IN.
6426 SQ. CM.
330 (144.7) 350 (158.9)
GGT-36S SHOWN
is a registerd trademark of APW Wyott®, A Middleby Company. All rights reserved.
2M-Z23811: APW Wyott Series Gas Griddles
2
GENERAL INSTALLATION DATA
This equipment is designed and sold for commercial use only by personnel trained and experienced
in its operation and is not sold for consumer use in and around the home nor for use directly by the
general public in food service locations.
The APW Wyott model griddles are equipped for use with the types of gas specified on the nameplate.
All units are shipped from the factory for use with natural gas. The unit can easily be converted
for use on propane gas: See propane gas.
-IMPORTANT-
The installation of the Appliance should conform to the NATIONAL FUEL
GAS CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS
COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE
CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR
CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES
WHERE APPLICABLE.
Improper installation, adjustment, alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing the equipment.
For your safety, do not store or use gasoline or other ammable vapors and liquids in
the vicinity of this or any other appliance. Keep the appliance area clear and free from
combustibles.
This appliance, its pressure regulator and its individual shuto valve must be disconnected
from the gas supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 PSIG (3.45KPA).
This appliance and its pressure regulator must be isolated from the gas supply piping system by closing
its individual manual shuto valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSIG (3.45KPA). For your protection, we recommend a qualified
installing agency install this appliance. They should be familiar with gas installations and your local
gas requirements. In any case, your gas company should be called to approve the final installation.
In addition, there should be posted, in a prominent location, detailed instructions to be followed in the
event the operator smells gas. Obtain the instructions from the local gas supplier.
For your safety, if you smell gas:
1. Do not touch electrical switches.
2. Extinguish any open ame.
3. Immediately call your gas company.
KEEP THE APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES.
CLEARANCE
For use on non-combustible countertops only.
Combustible and non-combustible material must be at least 48" (120cm) from the top of the
appliance and 6" (150mm) from the sides and back. Adequate clearance should also be
provided for proper operation and servicing.
AIR SUPPLY
Make certain not to obstruct the ow of combustion and ventilation air. Provisions for adequate air
supply must be furnished. The legs supplied with the unit must be installed. Make certain that air intake
openings in the bottom of the appliance are not obstructed. They are essential for proper combustion
and operation of the appliance.
CAUTION
CAUTION
CAUTION
CAUTION
2M-Z23811: APW Wyott Series Gas Griddles
3
EXHAUST CANOPY
It is essential that facilities be provided over the griddle to carry o fumes and gases. However,
the unit should not be directly connected to a ue or stack.
LEVELING UNIT
This griddle is supplied with (4) feet which must be screwed into the legs attached to the body.
Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" (43.75mm) for accurate
and perfect lineup with other units. After the griddle is in its final position, adjust the legs to
create 1/8 inch slant from back to front on the griddle plate. This will allow grease to run into
the grease gutter and provide the proper combustion air for the burners.
DO NOT INSTALL WITHOUT ATTACHING FEET - DO NOT REMOVE FEET.
GAS PIPING
Gas piping shall be of such size and so installed as to provide a supply of gas sucient to meet the full
gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to
determine if it has adequate capacity. Joint compound shall be used sparingly and only on the male threads
of the pipe joints. Such compounds shall be resistant to the action of LP gases. WARNING: Any loose
dirt or metal particles which are allowed to enter the gas lines on this appliance will damage the valve
and aect its operation. When installing this appliance, all pipe and fittings must be free from loose dirt.
GAS PRESSURE REGULATOR
A convertible pressure regulator is provided with each griddle. It should be connected to the inlet pipe at
the rear of the unit. The gas supply line is then connected to it. It is shipped set for 6" (15.24cm) water
column manifold pressure for use with natural gas.
MANUAL SHUT-OFF VALVE
A manual shut-o valve should be installed upstream from the union and within 6 feet (1.829m) of this
appliance.
LP [PROPANE] GAS CONVERSION
This griddle is equipped with fixed orifice hoods and is shipped from the factory for use on natural gas.
Note: GGM & GGT units use a #47 drill orice for natural gas and a #55 drill orice for propane.
To convert to propane gas, install the burner orifice hoods, located in the grease drawer, as follows:
1. Remove front panel by removing screws located on the front and the bottom.
2. Remove the burner(s) from the orifice hood(s). This is accomplished by removing the burner
mounting screw(s) and sliding the burner(s) o the hood(s).
3. Remove natural gas orifice hood(s) and install the propane hood(s) furnished.
4. Reinstall burner(s).
5. Reinstall front panel.
6. Remove the slotted, or hex-threaded, plug from the pressure regulator. Invert the plug and re-install.
The letters "LP" should now be visible on the plug. The regulator is now set for 10" (25.4cm) water
column.
7. Set manifold pressure to 10" (25.4cm) water column. A 1/8" pipe plug on the supply pipe can be
removed for attaching a pressure gauge.
CONNECTING GAS SUPPLY LINE
The gas inlet of the griddle is sealed at the factory to prevent entry of dirt. Do not remove this seal until
the actual connection is made to the gas supply line.
CHECKING FOR GAS LEAKS
Soap and water solution or other material acceptable for the purpose shall be used in locating gas
leakage. Matches, candle ame, or other sources of ignition shall not be used for this purpose.
Check entire piping system for leaks.
CAUTION
2M-Z23811: APW Wyott Series Gas Griddles
4
LIGHTING INSTRUCTIONS
When griddle is first lit, it will smoke until the preservation oils and impurities are burned o.
1. Turn o main valve to unit and wait 5 minutes to clear gas.
2. Turn o all knobs and pilot valves.
3. Turn on main valve and light all pilots.
4. Turn burner knobs to desired setting.
5. To turn burners o, turn knobs o.
NOTE: The griddles are equipped with standing pilots and should be lit immediately after the gas is
turned on.
Pilot ames can be lit and observed through the front panel view ports. However, best access for lighting the pilot is
from the bottom of the unit just behind the center wall.
PILOT LIGHT REGULATION
Adjust pilot light ames as small as possible, but high enough to light burner immediately when burner valve
is turned on high.
BURNER ADJUSTMENT (MODELS GGM)
1. Remove the front panel.
2. Turn burner valve knob to "HI" position.
3. Close the air shutter on the front of the burner to give a soft blue ame having luminous tips and open to a point
where the yellow tips disappear and a hard blue ame is obtained. Repeat for all burners.
BURNER ADJUSTMENT (MODELS GGT)
1. Remove the front panel.
2. Push dial in and set thermostat of one burner to 450°F (229.9°C).
3. Close the air shutter on the front of the burner to give a soft blue ame having luminous tips and open
to a point where the yellow tips disappear and a hard blue ame is obtained. Repeat for all burners.
BURNER OPERATION (MODELS GGM)
To ignite burners, turn burner valve knob to "HI" position. Each burner is controlled by an individual high-low, on-o
valve. An infinite number of temperatures may be obtained by turning the burner valve knob to any position between
high and low. For overnight shutdown, turn the valves to the "OFF" position.
SEASONING THE GRIDDLE SURFACE (NON-CHROMIUM SURFACES)
Clean the griddle surface thoroughly. After the griddle has been thoroughly cleaned, it should be seasoned to prevent
food from sticking. Before using, and after each thorough scouring, season the griddle heating surface in the following
manner:
1. Turn the temperature control dial to 350°F (174.9°C).
2. Using a clean cloth, not a spatula, spread a thin film of cooking oil over the griddle cooking surface. This film
should remain on the hot griddle surface 1/2 hour.
3. Remove excess oil and wipe clean.
4. Apply another film of cooking oil over the hot cooking area for another 1/2 hour and again remove excess oil and
wipe clean. The griddle surface should now be ready for use.
Even with careful seasoning food may, to some extent, stick to the griddle cooking surface until griddle
plate is "broken in."
2M-Z23811: APW Wyott Series Gas Griddles
5
COOKING (MODELS TD)
Set the thermostat dial knob to the temperature desired. After a short preheating period, the thermostat
will automatically maintain the selected temperature.
GREASE PAN
A grease pan is located at the front and can be removed for cleaning from the front. This pan should be
checked and emptied on a regular basis.
EXERCISE EXTREME CARE IN HANDLING THE GREASE PAN CONTAINING HOT GREASE.
GRIDDLE CARE (NON-CHROMIUM AREAS)
It takes very little time and eort to keep the griddle attractive and performing at top eciency. If grease
is permitted to accumulate, it will form a gummy cake and then carbonize into a hard substance which is
extremely dicult to remove. To prevent this condition, the following suggestions for cleanliness should
be followed:
1. After each use, scrape the griddle with a scraper or exible spatula to remove excess grease and
food. A waste drawer is provided for the scrapings. If there is an accumulation of burned on grease
and food, the griddle should be thoroughly scoured and reseasoned. Use pumice or griddle stone
while the griddle is warm. Do not use steel wool because of the danger of steel slivers getting into
the food.
2. Daily-use a clean cloth and good non-abrasive cleaner to clean the stainless steel body of the griddle.
Wipe the polished front with a soft cloth.
3. At least once a day remove the waste drawer and wash in the same way as an ordinary cooking
utensil. The drawer is removed by pulling forward, up and out.
TEMPERATURE CONTROL
GGT: The temperature controls are combination “ON/OFF” switches and thermostats. Turning the dial
knob automatically maintains the selected heat range. There is one thermostat for every twelve [12] inch
(305 mm) wide section that operate independently.
GGM: To ignite burners, turn burner valve knob to highest temperature position. Each burner is controlled
by an individual high–low, on/o valve. Any temperature in the operable range may be obtained by turning
the burner valve knob to any position between high and low and adjusting for time and application. For
over- night shutdown, turn the valves to the “OFF” position.
COOKING
GGT: Set the thermostat dial knob at the desired temperature. After a short pre-heating period, the
thermostat will automatically maintain the selected temperature.
GGM: Adjust the knob to the desired area in the heat range. Once the desired heat is reached make
adjustments over time to maintain target heat.
IDLING: During idle periods, to save on operating costs, lower the temperature setting of the thermostat
to about 250°F (121°C) on thermostatic models and to a low heat setting on manual models. It is not
necessary to maintain cooking temperature during idle periods, as the griddle can quickly be reheated to
the desired temperature.
SIGNAL LIGHTS: On thermostatic models, each thermostat has its own signal light which indicates when
the unit’s control knob is not in the o position.
CAUTION
2M-Z23811: APW Wyott Series Gas Griddles
6
30
35
33
3032
31
9
REAR PANEL
LEFT SIDE—PANELS
GGT-36S shown
23444 262626 1116
4
18
36
29
28
27
FRONT—PANEL AND CONTROLS
RIGHT SIDE—PANELS
GGT-36S shown
is a registerd trademark of APW Wyott®, A Middleby Company. All rights reserved.
2M-Z23811: APW Wyott Series Gas Griddles
7
A
1
34
4
14
12
35
14
23
18
6
7
10
13
17
21
228
31
31
4
4
3
19
27
20 15 14
THERMOSTAT AND BURNERS
GGT-36S shown
THERMOSTAT
[GGT MODELS ONLY]
is a registerd trademark of APW Wyott®, A Middleby Company. All rights reserved.
2M-Z23811: APW Wyott Series Gas Griddles
8
PARTS LIST
Some items are included for illustrative purposes only and in certain instances may not be available.
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE 1
INCLUDE MODEL AND SERIAL NUMBER OF 4
P/N MODEL PART NUMBER QTY DESCRIPTION PAGE NO
1
GGM-24S
2F-Z5949
2
U-BURNER 7
GGM-36S 3
GGM-48S 4
GGT-24S 2
GGT-36S 3
GGT-48S 4
2A LL G3-Z6036 2 DRAWER SLIDE 7
3
GGM-24S
G3-Z5946
2
COVER, GAS 7
GGM-36S 3
GGM-48S 4
GGT-24S 2
GGT-36S 3
GGT-48S 4
4
GGM-24S
2C-8823
46
SCREW, #8 X 0.375 - INCH 7
GGM-36S 59
GGM-48S 58
GGT-24S 46
GGT-36S 55
GGT-48S 58
5A LL 2P-1453 1 MANIFOLD PLUG NP
6
GGM-24S
2V-6671
2
VALVE, PILOT
GGM-36S 3
GGM-48S 4
GGT-24S 2
GGT-36S 3
GGT-48S 4
7
GGM-24S
2V-Z6647
2
BURNER, PILOT 7
GGM-36S 3
GGM-48S 4
GGT-24S 2
GGT-36S 3
GGT-48S 4
8
GGM-24S/GGT-24S G3-Z5919 1 PANEL, BOTTOM 24 INCH
7GGM-36S/GGT-36S G3-Z5929 1 PANEL, BOTTOM 36 INCH
GGM-48S/GGT-36S G3-Z5939 1 PANEL, BOTTOM 48 INCH
9
GGM-24S/GGT-24S G3-Z5953 1 PANEL, REAR 24 INCH
6GGM-36S/GGT-36S G3-Z5955 1 PANEL, REAR 36 INCH
GGM-48S/GGT-36S G3-Z5957 1 PANEL, REAR 48 INCH
NOTE: Side references are from the operator’s point-of-view – from the front of the unit. Items labeled “NS”
are non-serviceable. Items labeled “NP are not pictured.
2M-Z23811: APW Wyott Series Gas Griddles
9
Some items are included for illustrative purposes only and in certain instances may not be available.
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE 2
INCLUDE MODEL AND SERIAL NUMBER OF 4
P/N MODEL PART NUMBER QTY DESCRIPTION PAGE NO
10 ALL G3-6243047 1 GREASE CHUTE 7
11
GGM-24S/GGT-24S G5-Z4812
1
FLUE, 24 INCH
6GGM-36S/GGT-36S G5-Z48131 FLUE, 36 INCH
GGM-48S/GGT-36S G5-Z4814 FLUE, 48 INCH
12
GGM-24S
2C-2555
2
NUT, #8-32 - ACORN NP
GGM-36S 3
GGM-48S 4
GGT-24S 2
GGT-36S 3
GGT-48S 4
13 ALL G3-Y7046 1 GREASE DRAWER 7
14
GGM-24S G3-624306
1
MANIFOLD, 24 INCH WITHOUT THERMOSTAT
[MANUAL CONTROL]
7
GGM-36S G3-624306
MANIFOLD, 36 INCH WITHOUT THERMOSTAT
[MANUAL CONTROL]
GGM-48S G3-624306
MANIFOLD, 48 INCH WITHOUT THERMOSTAT
[MANUAL CONTROL]
GGT-24S G3-624307 MANIFOLD, 24 INCH WITHOUT THERMOSTAT
GGT-36S G3-624307 MANIFOLD, 36 INCH WITHOUT THERMOSTAT
GGT-48S G3-624307 MANIFOLD, 48 INCH WITHOUT THERMOSTAT
15
GGM-24S
2A-9369
2
FITTING, ORIFICE 7
GGM-36S 3
GGM-48S 4
GGT-24S 2
GGT-36S 3
GGT-48S 4
16
GGM-36S
G5-Z4817 1 FULE DIVIDER 6
GGM-48S
GGT-36S
GGT-48S
17
GGM-24S
G3-GD0036
2
PROBE TUBE ASSEMBLY NP
GGM-36S 3
GGM-48S 4
GGT-24S 2
GGT-36S 3
GGT-48S 4
18
GGT-24S
2T-Z4293
2
THERMOSTAT 6GGT-36S 3
GGT-48S 4
PARTS LIST
2M-Z23811: APW Wyott Series Gas Griddles
10
Some items are included for illustrative purposes only and in certain instances may not be available.
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE 3
INCLUDE MODEL AND SERIAL NUMBER OF 4
P/N MODEL PART NUMBER QTY DESCRIPTION PAGE NO
19
GGT-24S
2K-Y7111
2
ASSEMBLED FITTING, 90 DEG 7GGT-36S 3
GGT-48S 4
20
GGM-24S
2K-Z4921
2
CORRUGATED BURNER TUBE 7
GGM-36S 3
GGM-48S 4
GGT-24S 2
GGT-36S 3
GGT-48S 4
21
GGT-24S
G3-Z4398
2
BULB CAP NPGGT-36S 3
GGT-48S 4
22
GGT-24S
2C-6517
6
NUT, 1/4-20 NPGGT-36S 9
GGT-48S 12
23 ALL 2J-Z0792 1 PRESSURE REGULATOR 6, 7
24
GGT-24S
G3-Y9531
2
INSULATOR NPGGT-36S 3
GGT-48S 4
26
GGM-24S
2C-Z2893
6
NUT, #10-24 6
GGM-36S 8
GGM-48S 8
GGT-24S 6
GGT-36S 8
GGT-48S 8
27
GGM-24S
2R-8706320
2
KNOB METAL COOKLINE, .375 6
GGM-36S 3
GGM-48S 4
GGT-24S 2
GGT-36S 3
GGT-48S 4
28
GGM-24S
2M-Z15449
2
KNOB LABEL, WITHOUT THERMOSTAT [MANUAL
CONTROL]
6
GGM-36S 3
GGM-48S 4
GGT-24S
2M-Z15450
2
KNOB LABEL, WITH THERMOSTATGGT-36S 3
GGT-48S 4
29 ALL 2M-8830100 1 BADGE, APW WYOTT 6
30 ALL G3-Z5945 2 SIDE PANEL 6
31 ALL 2A-Z5942 4 LEG 6, 7
PARTS LIST
2M-Z23811: APW Wyott Series Gas Griddles
11
Some items are included for illustrative purposes only and in certain instances may not be available.
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE 4
INCLUDE MODEL AND SERIAL NUMBER OF 4
P/N MODEL PART NUMBER QTY DESCRIPTION PAGE NO
32 ALL G3-624302 1 LINER ASSEMBLY, LEFT 6
33 ALL G3-624303 1 LINER ASSEMBLY, RIGHT 6
34
GGM-24S/GGT-24S G3-Z5915
1
CENTER WALL, 24 INCH
7GGM-36S/GGT-36S G3-Z5925 CENTER WALL, 36 INCH
GGM-48S/GGT-36S G3-Z5935 CENTER WALL, 48 INCH
35
GGM-24S G4-TC0096
1
TOP WELDMENT, 24 INCH WITHOUT
THERMOSTAT [MANUAL CONTROL]
6, 7
GGM-36S G4-TC0102
TOP WELDMENT, 36 INCH WITHOUT
THERMOSTAT [MANUAL CONTROL]
GGM-48S G4-TC0105
TOP WELDMENT, 48 INCH WITHOUT
THERMOSTAT [MANUAL CONTROL]
GGT-24S G4-TC0097
TOP WELDMENT, 24 INCH WITHOUT
THERMOSTAT
GGT-36S G4-TC0103
TOP WELDMENT, 36 INCH WITHOUT
THERMOSTAT
GGT-48S G4-TC0106
TOP WELDMENT, 48 INCH WITHOUT
THERMOSTAT
36
GGM-24S G3-Z15799
1
PANEL, 24 INCH WITHOUT THERMOSTAT
[MANUAL CONTROL]
6
GGM-36S G3-Z15807
PANEL, 36 INCH WITHOUT THERMOSTAT
[MANUAL CONTROL]
GGM-48S G3-Z15809
PANEL, 48 INCH WITHOUT THERMOSTAT
[MANUAL CONTROL]
GGT-24S G3-Z15806 PANEL, 24 INCH WITHOUT THERMOSTAT
GGT-36S G3-Z15808 PANEL, 36 INCH WITHOUT THERMOSTAT
GGT-48S G3-Z15810 PANEL, 48 INCH WITHOUT THERMOSTAT
38W
GGT-24S
2T-Y7590
2 STEM, THERMOSTAT
NPGGT-36S 3
GGT-48S 4
39
GGM-24S
2V-Y8832
2 MANUAL GAS CONTROL VALVE
NPGGM-36S 3
GGM-48S 4
PARTS LIST
LIMITED EQUIPMENT WARRANTY
APW warrants to the original purchaser of new APW's products to be
free from defects in material or workmanship, under normal and proper
use and maintenance service as specified by APW and upon proper
installation and start-up in accordance with the instructions
supplied with each APW unit. APWs obligation under this warranty is
limited to a period of one [1] year from the date of original installation, or
eighteen [18] months from original invoice date, whichever occurs first.
Defects that occur as a result of normal use, within the time period and
limitations defined in this warranty, will at APWs’ discretion have the parts
replaced or repaired by APW or a APWs-authorized service agency.
THIS WARRANTY IS SUBJECT TO ALL LISTED CONDITIONS
Repairs performed under this warranty are to be performed by an
APW authorized service agency. APW will not be responsible for
charges incurred or service performed by non-authorized repair
agencies. In all cases, the nearest APW-authorized service agency must be
used. APW will be responsible for normal labor charges incurred in
the repair or replacement of a warrantied product within 50 miles
(80.5 km) of an authorized service agency. Time and expense charges
for anything beyond that distance will be the responsibility of the owner.
All labor will need to be performed during regular service hours. Any
overtime premium will be charged to the owner. For all shipments
outside the U.S.A. and Canada, please see the International Warranty
for specific details. It is t
he responsibility of the owner to inspect
and report any shipping damage claims, hidden or otherwise, promptly
following delivery. No mileage or travel charges will be honored on any
equipment that is deemed portable. In general, equipment with a cord
and plug weighing less than 50 lb. (22.7 kg) is considered portable and
should be taken or shipped to the closest authorized service agency,
transportation prepaid.
CONTACT
Should you require any assistance regarding the operation or maintenance
of any APW Manufacturing; phone or email our service department. In all
correspondence provide the model number and serial number of the unit
needing service; include the voltage or gas type.
Normal Business Hours: 8:00 a.m. to 4:30 p.m. Central
Telephone: 800-264-7827 Tech Service Option 2
www.apwwyott.com
WARRANTY EXCLUSIONS
THE FOLLOWING WILL NOT BE COVERED UNDER WARRANTY.
APWs’ sole obligation under this warranty is limited to either repair
or replacement parts, subject to the additional limitations
detailed below. This warranty neither assumes nor authorizes any
person to assume obligations other than those expressly
covered by this warranty.
Any product which has not been used, maintained, or installed in
accordance with the directions published in the appropriate
installation sheet and/or owner’s manual, including incorrect gas or
electrical connection. APW is not liable for any unit which has been
mishandled, abused, misapplied, subjected to harsh chemicals,
modified by unauthorized personnel, damaged by flood, fire, or other
acts of nature [or God], or which have an altered or missing serial
number.
Installation, labor, and job checkouts, calibration of heat controls,
air and gas burner/bypass/pilot adjustments, gas or electrical system
checks, voltage and phase conversions, cleaning of equipment, or
seasoning of griddle surface.
Replacement of fuses or resetting of circuit breakers, safety
controls, or reset buttons.
Replacement of broken or damaged glass components, quartz
heating elements, and light bulbs.
Labor charges for all removable and consumable parts in gas
charbroilers and hotplates, including but not limited to burners,
grates, and radiants.
Any labor charges incurred by delays, waiting time, or operating
restrictions that hinder a service technician’s ability to perform
service.
Replacement of parts that fail or are damaged due to normal wear
or labor for replacement of parts that can be replaced during a daily
cleaning routine, such as but not limited to silicone belts, PTFE non-
stick sheets, control labels, knobs, bulbs, fuses, quartz heating
elements, baskets, racks, and grease drawers.
Any economic loss of business or profits.
Non-OEM parts. Use of non-OEM parts without APWs’ approval
will void the warranty.
Units exceeding one [1] year from original installation date, or
more
than eighteen [18] months from original invoice date, whichever
comes first.
ADDITIONAL WARRANTIES
Specific/chain-specific equipment may have additional and/or
extended warranties.
The
foregoing warranty is in lieu of any and all other warran�es
expressed or implied and cons�tutes the en�re warranty.
PAGE INTENTIONALLY LEFT BLANK
APW Wyott • www.apwwyott.com/
265 Hobson St. • Smithville, TN 37166
Telephone: (800)-264-7827 • Fax: (314)-781-5445
Printed in the U.S.A. • 2M-Z12966 • Rev - (12/11/2020)
Specifications are subject to change without notice.
is a registerd trademark of APW Wyott®, A Middleby Company. All rights reserved.